Our Transformer Manufacturing Range

 

AMAR TRANSFORMERS Pvt. Ltd. is an ISO : 9001-2008 certified company established in 1990 and engaged in Design, Manufacture and Supply of Industrial Transformers and Chokes, meeting National and International Standards. From the beginning company has recorded consistent and impressive growth. We are supplying Transformers and Chokes of varying capacities to the number of reputed Industries and Multinational Companies. AMAR TRANSFORMERS has a well equipped manufacturing facility admeasuring 8000 sq. fit near to TATA MOTORS supported by dedicated team of technicians and skilled workmen, assure quality output.

 

Our Products range includes:

1. Control Transformers 2. Isolation Transformer 3. Ligthning Transformer 4. Detuned Reactor 5. Air Core Reactor 6. Special type transformer. 7. Oil cooled transformer 8. Auto transformer

 

Below is Our Product Range

LIGHTNING TRANSFORMER
TECHNICAL SPACIFICATIONS
  - 3 phase, 50 Hz 100KVA-500KVA
  - Type: Oil / Dry
  - Tap Changer/Links: Off Circuit
  - Tapping Range: +7.5% to - 7.5% @2.5% for OCTC
  - Group- Dyn11, YNd11, Dzn0 or any specific.
  - Painting: As per IS/IEC standards.
  - Standards: IS 2026, IEC 60726 & IEC 60076.
  Features
  - Specially designed Step Core for reduced Losses
  - Multiple Conductors using for better Heat Dissipation.
  - Vacuum Pressure Impregnated for better penetration
  - Mechanical Sturdy Design to withstand Vibrations
  - Thermostats embedded in Winding for Over Temperature Protection
  - Round Coils for better Short Circuit withstand Capacity
  - Low Noise



AUTO TRANSFOMRER
TECHNICAL SPACIFICATIONS
TECHNICAL SPACIFICATIONS
- 1/3 phase, 50 Hz ,-2000KVA
- Voltage Class: Up to 33KV Or Any specific
- Type: Oil / Dry
- Insulation Class: A/B/F/H
- Standard: IS 2026.
- Vector group: YNa0, ZNa0.
- Tapings: As per costumer requirement.
FEATURES

- Trouble free performance
- Low maintenance
- Long working life
- Competitive rate
- Specification as per the requirement of the client
- Shock resistance
- Helps to prevent motor from starting current damage





DETUNED REACTOR
TECHNICAL SPACIFICATIONS
TECHNICAL SPECIFICATIONS:
- From 5KVAr to 300KVAr
- Filter factor 5.67%, 7%, 14%SystemVoltage:380V,415V,433V
- Standards Followed: IS-5553-1990
- Linearity: Standard 1.73 times on request can change.
- Insulation Class H or Class F
- Termination: For Copper wound - Nickel Platted Copper bus bar. For Aluminum Wound - Aluminum bus bar.
- Noise level less than 60 dB.
FEATURES
:
- For Triplen and Non-Triplen Harmonic suppression though PF Capacitors.
- Line Voltage for series combination of Reactor & capacitors: 380V, 415V, 433V, 440V AC.50H 3ph supply.
- Current: Continuous RMS value: 130% of the rated current.
- Electrolytic grade copper/aluminum winding.
- Operating ambient temperature-10 to +50 Deg C.
AIR CORE REACTORS
TECHNICAL SPACIFICATIONS
TECHNICAL SPECIFICATIONS:
- Specification: 50Hz
- Rating wide range per customer requirement.
- Voltage : 433/690/3.3/6.6/7.2/12/22/33 KV
- Application : Detuned/Tuned harmonic filter
- Termination : For Copper wound - Nickel Platted Copper bus bar. For Aluminum - Aluminum bus bar.
- Standard :IS-5553-1990
FEATURES

- Design service life in excess of 30 years
- Epoxy impregnated, fiberglass encapsulated construction
- Aluminum construction throughout with all current carrying connections welded
- Highest mechanical and short circuit strength
- Essentially zero radial voltage stress, with uniformly graded axial voltage distribution between terminals
- Low noise levels are maintained throughout the life of the reactor
- Weatherproof construction, with minimum maintenance requirements
- Designs available in compliance with ANSI/IEEE, IEC and other major standards.
OIL COOLED REACTORS
TECHNICAL SPACIFICATIONS
Specification : 50Hz
- Rating : wide range As per customer requirement.
- Voltage : 3.3/3.6/6.6/7.2/12/22/33 KV
- Application : Detuned/Tuned harmonic filter
- Insulation class : A/B
- Standard :IS-5553-1990


















SCOTT TEE TRANSFORMER
TECHNICAL SPACIFICATIONS
Connection for poly phase using two special single phase transformers. Usually used to change from two phase to three phase or three phase to two phase.
Features
- High reliability
- Standard design.
- Superior short circuit intensity based on advanced technology.
- Low noise
- High efficiency considering living environment.













Contact Us

We are always happy to hear from you and there are various ways you can contact us. Feel free to contact us for your any type of transformer requirement.

 

Company:
Full Name:
Address:
Phone:
Email:
Questions / Comments: